<LOGO>
FM Transmitter Measurement Report
Created: 2024-06-24 04-21-42
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 48 dBuV R-PCE
Pilot RDS Phase Difference
6.0 kHz 2.6 kHz -87 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
9 kHz 10 kHz 18935 0,2377
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-3,1 dBr -1,89 dBr -0,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 4:21, 24.06.2024
RT
"Zpravy z regionu - rozhovory - dobre rady - souteze "
AF EON
88.9, 93.7, 98.6, 101.0, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 10 kHz MIN: 9 kHz % above 77 kHz: 0,2377 Acquired: 2024/06/24 4:21:39 Total samples: 18935 Equivalent time: 0:15:46 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: -0,9 dBr MIN: -3,1 dBr AVE: -1,89 dBr % above 0,2 dBr: 0,0 Last value: -2,5 dBr (2024/06/24 4:21:38) 04:08 04:10 04:12 04:14 04:16 04:18 04:20 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality